Refine your search:     
Report No.
 - 
Search Results: Records 1-19 displayed on this page of 19
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Oral presentation

Development of image-analysis method of plutonium samples by imaging plate

Mizuniwa, Harumi; Takasaki, Koji; Horikoshi, Yoshinori; Suzuki, Kazunori; Shioya, Satoshi; Sagawa, Naoki; Kurosawa, Shigeyuki*

no journal, , 

no abstracts in English

Oral presentation

Development of a frog voxel phantom

Kinase, Sakae; Saito, Kimiaki

no journal, , 

no abstracts in English

Oral presentation

Study on the radiological assessment of long-term multilateral radioactive effluents

Nakano, Masanao

no journal, , 

There are 429 nuclear power plants which generate about 390 GWe in total, at the end of 2006. Also commercial reprocessing plants have been operated in Japan, France and United Kingdom. The liquid effluent such as tritium has been released from each facility with authorization. The each safety assessment confirms that local environmental impact would be small enough. However, multilateral long-term assessment over the border from plural countries will be necessary, because of the increase of both the interest for environmental problem and demand for nuclear energy. In this study, the author is calculating multilateral long-term diffusion of radionuclides which has been discharged from nuclear facilities in the world, and assessing the environmental impact to the world ocean, using a computer code LAMER (Long-term Assessment ModEl of Radionuclides in the Oceans) developed by JAEA.

Oral presentation

Neutron dosimetry in an aircraft, 2; Model calculation

Sato, Tatsuhiko; Yasuda, Hiroshi*; Takada, Masashi*; Yajima, Kazuaki*; Nakamura, Takashi

no journal, , 

We developed the PHITS-based Analytical Radiation Model in the Atmosphere.

Oral presentation

Replacement of the criticality alarm system in the plutonium conversion development facility

Hikinuma, Yuichi; Sanada, Yukihisa; Hasegawa, Ichiro; Kanazawa, Nobuyuki; Kawai, Keiichi*; Momose, Takumaro

no journal, , 

no abstracts in English

Oral presentation

Neutron spectrometry in the MOX fuel fabrication process for the experimental FBR Joyo

Yoshida, Tadayoshi; Tsujimura, Norio; Sagawa, Naoki; Shoji, Shigeru

no journal, , 

no abstracts in English

Oral presentation

Outline of moderated neutron calibration fields simulating workplaces of MOX fuel facilities

Tsujimura, Norio; Yoshida, Tadayoshi; Takada, Chie

no journal, , 

no abstracts in English

Oral presentation

Provisional dose calculation to examine the radiation protection in geological disposal of high-level radioactive waste

Nakai, Kunihiro*; Kai, Michiaki*; Okoshi, Minoru; Kato, Tomoko; Yamaguchi, Tetsuji; Sasaki, Takayuki*; Hattori, Takatoshi*; Miyazaki, Shinichiro*; Yoshizawa, Yuji*; Higuchi, Natsuko*; et al.

no journal, , 

no abstracts in English

Oral presentation

The Comparison of biokinetic model between the human alimentary tract model of ICRP Publ.100 and the gastrointestinal model of Publ.30

Hato, Shinji; Homma, Toshimitsu

no journal, , 

The international commission on radiological protection (ICRP) was published the human alimentary tract model (HATM) on the ICRP publication 100 (2006). The HATM is a new model replaced the gastrointestinal model of ICRP publication 30. The publication 30 was a model applied to workers, though it's model was applied to public by the f1 value of age dependence. And it's model also did not have the oesophagus. As a result, the HATM was developed for the improvement of their problems and findings since publication 30. Our presentation quantitatively show some difference between two models by simulating retention in organ.

Oral presentation

Discrimination of the variation of ambient radiation dose rate due to radioactivity discharged from nuclear facility during rainfall by using the correlation between the variations observed at neighboring monitoring posts

Takeyasu, Masanori; Sugai, Masamitsu*; Onuma, Toshimitsu; Takeishi, Minoru; Matsuura, Kenichi

no journal, , 

The variation of ambient radiation dose rate due to the ground deposition of atmospheric radon decay products during rainfall becomes an interference factor, when the variation of the dose rate due to radioactivity discharge from nuclear facility is discriminated. In this study, the variation due to the radioactivity discharge facilities during rainfall was quantified by using the correlation relationship of the variation of the dose rate observed neighboring monitoring posts during rainfall.

Oral presentation

The Evaluation of the radon dose of radioactivity in high-level radioactive waste geological disposal facility

Yoshizawa, Yuji*; Kai, Michiaki*; Okoshi, Minoru; Kato, Tomoko; Yamaguchi, Tetsuji; Sasaki, Takayuki*; Hattori, Takatoshi*; Miyazaki, Shinichiro*; Higuchi, Natsuko*; Tokonami, Shinji*; et al.

no journal, , 

no abstracts in English

Oral presentation

Environmental radiation dose estimation method for hypothetical accident considering radioactive decay during atmospheric dispersion of short-lived radionuclide

Takeyasu, Masanori; Takeishi, Minoru; Onuma, Toshimitsu

no journal, , 

Environmental radiation dose estimation method for hypothetical accident considering radioactive decay during atmospheric dispersion of radionuclide with short-lived half life.

Oral presentation

Coordination of radiation cntrol practices in JAEA

Uezu, Yasuhiro; Tobita, Kazunori; Yamaguchi, Takenori; Momose, Takumaro; Murakami, Hiroyuki; Furuta, Sadaaki; Yamaguchi, Yasuhiro

no journal, , 

JAEA was established on October 1st, 2005 by integrating the Japan Atomic Energy Research Institute and the Japan Nuclear Cycle Development Institute. In these institutes, there were a several radiation control methods or original radiation control levels. After establishing JAEA, in order to make a harmonization of radiation control methods and levels, applications of these are investigated under actual situations.

Oral presentation

Neutron monitoring at the boundaries of control areas in MOX facilities with TLD

Nakagawa, Takahiro; Takada, Chie; Sekine, Nobuyuki*; Takayasu, Tetsuya*; Tsujimura, Norio

no journal, , 

no abstracts in English

Oral presentation

Study on source term for emergency action plan on a criticality accident

Takada, Chie; Nakagawa, Takahiro; Tsujimura, Norio

no journal, , 

Study on source term for emergency action plan on a criticality accident.

Oral presentation

Observation of radiation fluctuations associated with winter thunderstorm activities and the generation of runaway electrons by atmospheric radionuclides

Torii, Tatsuo; Okuyama, Shinichi; Nozaki, Tatsuo; Sugita, Takeshi*; Muraki, Yasushi*

no journal, , 

The dose rate might increase when the winter thunderstorm generated in the Sea of Japan coast has been generated. We report on events observed around Monju, and report this case on the radiation behavior in the thundercloud electric field thought about as a source of the radiation.

Oral presentation

Validation of dosimetric models and assessment of protective actions using Chernobyl $$^{131}$$I release data

Homma, Toshimitsu; Matsubara, Takeshi*; Kimura, Masanori; Takahara, Shogo

no journal, , 

no abstracts in English

Oral presentation

Application of multi-channel rate meter to $$gamma$$-ray spectrometer

Saito, Kei; Takashima, Hideki; Emori, Shuichi; Soma, Susumu; Takada, Chie

no journal, , 

no abstracts in English

Oral presentation

Dose evaluation with closed space in vector space composed of radiation detector outputs

Hashimoto, Makoto; Sohn, S.-K.*; Iimoto, Takeshi*; Kosako, Toshiso*

no journal, , 

It is known that the ratios of multiple detectors outputs and objective values compose closed convex in vector space forming with these ratios in the case of optimum obcective value evaluation, such as dose evaluation, with multiple radiation detectors. Neutron dose evaluation method with this method is discussed. A neutron detector with high sensitivity for thermal neutrons and fast neutrons combined was applied for dose evaluation experiment with this method. The response of the detector was simulated by calculation and experimentally validated with mono-energy neutron and RI. A vector space with tis detector was calculated. It is confirmed that the simulated outputs of detectors with various types of neutron field and experimental outputs plotted in this vector space are arranged in closed convex.

19 (Records 1-19 displayed on this page)
  • 1